This seems to have all of the features that we need (-40 C delta), sealed, and has a dew remover built-in, for a decent price: https://player-one-astronomy.com/product/uranus-m-pro-usb3-0-mono-cooled-camera-imx585/ . Any thoughts?
Also, I want to use this for solid graphene powder. Normally in ...
Search found 5 matches
- Mon Jun 30, 2025 1:08 pm
- Forum: OpenRAMAN
- Topic: OpenRAMAN Suitability for Graphene
- Replies: 8
- Views: 19986
- Sun Jun 29, 2025 5:25 pm
- Forum: OpenRAMAN
- Topic: OpenRAMAN Suitability for Graphene
- Replies: 8
- Views: 19986
Re: OpenRAMAN Suitability for Graphene
Understood. Do you have any recommendations for a cooled CMOS camera that will not break the bank
? Morovian cameras look quite expensive.

- Sat Jun 28, 2025 7:52 am
- Forum: OpenRAMAN
- Topic: OpenRAMAN Suitability for Graphene
- Replies: 8
- Views: 19986
Re: OpenRAMAN Suitability for Graphene
Thanks for the detailed response! How do you feel about using the Hamamatsu S11639? That is the one I can readily buy with the driver board.
- Fri Jun 27, 2025 8:08 am
- Forum: OpenRAMAN
- Topic: OpenRAMAN Suitability for Graphene
- Replies: 8
- Views: 19986
Re: OpenRAMAN Suitability for Graphene
Hi Luc,
I actually already have a fiber laser with a 0.1 nm linewidth, but it outputs to free-space. I think the performance edition baseplate would still be suitable, but please correct me if I am wrong.
For the CCD vs CMOS, I was talking to a professor that builds out these Raman spectrometers ...
I actually already have a fiber laser with a 0.1 nm linewidth, but it outputs to free-space. I think the performance edition baseplate would still be suitable, but please correct me if I am wrong.
For the CCD vs CMOS, I was talking to a professor that builds out these Raman spectrometers ...
- Thu Jun 26, 2025 9:11 am
- Forum: OpenRAMAN
- Topic: OpenRAMAN Suitability for Graphene
- Replies: 8
- Views: 19986
OpenRAMAN Suitability for Graphene
Hello Luc and Board,
I'm looking to build either the starter or performance edition of the OpenRaman project. We want to take spectra of graphene samples and was wondering as to the suitability of OpenRaman for this.
The graphene samples we will take is a mixture of few-layer and multi-layer ...
I'm looking to build either the starter or performance edition of the OpenRaman project. We want to take spectra of graphene samples and was wondering as to the suitability of OpenRaman for this.
The graphene samples we will take is a mixture of few-layer and multi-layer ...